What was found
CABIN FLOOR PANEL 242AF HAS EDGE/FACE SHEET DAMAGE. EVALUATED AND FOUND MISSING PLIES AND DAMAGE TO CORE AT EDGE. TAP TEST GOOD. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-10. APPLIED POTTING COMPOUND TO CORE AT EDGE AS MARKED IAW SRM 53-00-50-2R-10 STEP 3 A-G. CURED AT 120 DEGREES. CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50-2R-1 STEP 3 A; C; E-F. VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. RESIN, POTTING COMPOUND, FABRIC. BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES. REPAIRED CABIN FLOOR PANEL 242AF UPPER SIDE IAW SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-0 REPAIR GENERAL.