What was found
CORROSION ON L/H FWD EMERGENCY EXIT DOOR CLOSEOUT PANEL KICKSTAND BRACKET / [01] BLENDED LIGHT SURFACE CORROSION PER SRM 51-10-02. REMOVED .003?OF MATERIAL. REMAINING THICKNESS .047?.;[02] VERIFIED CORROSION REMOVAL AND REMAINING THICKNESS.;[03] REPAIRED BLENDED AREA L/H FWD EMERGENCY EXIT DOOR CLOSEOUT PANEL KICKSTAND BRAKET (P/N 411A2854-9) PER EA 22-125-01200 (TTG8Q00C0D3M) AND (TTG8Q00C4DCT);[04] REPAIRED BLENDED AREA L/H FWD EMERGENCY EXIT DOOR CLOSEOUT PANEL KICKSTAND BRACKET (P/N 411A2854-9) PER EA 22-125-01200 (TTG8Q00C0D3M) AND (TTG8Q00C4DCT). INSPECTION C/W.