What was found
A125-01 - BS663; RBL41; WL172 - CRACKED ATTACH ANGLE (ECS BAY AFT WALL TO CENTER TANK LOWER SKIN) EXTERNAL TO FUEL TANK. TRIMMED OUT DAMAGED SECTION OF VAPOR BARRIER ATTACH ANGLE IAW SRM 57-10-10-2R-5;] APPLIED EWIS PROTECTION TO REPAIR AREA IAW AMM 20-60-07; TREATED AND PRIMED REPAIR PARTS AND BARE SURFACES IN REPAIR AREA IAW SRM 57-10-10-2R-5;COMPLETED INSTALLATION AND APPLIED INTERNAL CAP SEALANT TO ALL HORIZONTAL FLANGE FASTENERS IAW SRM 57-10-10-2R-5;COMPLETED INSTALLATION OF ALL REPAIR PARTS AND REMOVED/DISPLACED FOM PARTS IAW SRM 57-10-10-2R-5 APPLIED CAP SEAL AND FILLET SEAL IAW SRM 57-10-10-2R-5 APPLIED CIC TO REPAIR AREA IAW SRM 57-10-10-2R-5; ACCOMPLISHED CENTER TANK LEAK CHECK IAW AMM 28-11-00-400-801.