What was found
R/W T/E PANEL 661BB HAS SEVERAL PULLED FASTENER HOLES (MARKED) / [01] IDENTIFIED PANEL 661BB MATERIAL IAW SRM 57-51-01-0I-1 TABLE 3 FIGURE 3 ITEM 9. DAMAGE TO MULTIPLE FASTENER HOLES AS MARKED ARE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-51-01-1A-1 PARAGRAPH 4.B(5). DAMAGED FASTENER HOLES ARE REPAIRABLE IAW SRM 51-70-04-2R-9 AS DIRECTED BY SRM 57-51-01-2R-1.<BR><BR>REMOVED DAMAGE AT DISCREPANT FASTENER HOLES AND PREPPED HOLES FOR SLURRY RESIN MIX APPLICATION. NO CONTAMINATION NOTED. IAW SRM 51-70-04-2R-4 PARAGRAPH 4.A-C. OKAY TO APPLY SLURRY RESIN MIX.;[02] VALIDATED REPAIR PER SRM 51-70-04-2R-9;[03] CORRECTION TO ITEM 1 AT DAMAGE REMOVAL: 'IAW SRM 51-70-04-2R-4' TO SAY 'IAW SRM 51-70-04-2R-9';[04] VERIFIED CORRECTIVE ACTIONS 1-3<BR><BR>VALIDATED REPAIR PER SRM 51-70-04-2R-9<BR><BR>OKAY TO APPLY SLURRY RESIN MIX.;[05] APPLIED SLURRY RESIN MIX USING BMS8-301 CL1 LOT# JH1GAA7833 AND MILLED GLASS TO DISCREPANT HOLES IAW SRM 51-70-04-2R-9 PARAGRAPH 4.D-E.;[06] CURED ALL SLURRIED FASTENER HOLES PER SRM 51-70-04-2R-9 PARA 4.F. USING THERMOMETER ID: ATS2192 DUE 07/2022.;[07] SANDED SLURRY MIX FLUSH TO SURROUNDING SKIN; REMOVED FINISH IN REPAIR AREA ; AND CLEANED ALL IAW SRM 51-70-04-2R-9 PARA'S 4.G - 4.I.;[08] FABRICATED REPAIR PLIES AND INSTALLED USING BMS9-3 LOT# 1491986-1 AND RESIN BMS8-301 CL1 LOT# JH1GAA7833. VACUUM BAGGED REPAIR AND LEAK CHECKED GOOD USING VACUUM GAUGE ID: E11543 CAL DUE 08/22 IAW SRM 51-70-04-2R-9 PARAGRAPH 4.J-L.;