What was found
CRACKED INTERCOSTAL AT STA 312+5; RBL 31; WL 208. CRACKED INTERCOSTAL AT STA 312+5; RBL 31; WL 208 P/N 141A5410-12; FOUND TO BE OUT LIMITS DUE TO NO ALLOWABLE DAMAGE IN SRM; IT WILL BE REPAIRABLE BY REPLACEMENT I.A.W SRM 51-10-02-0G PAR 9C .; REMOVED INTERCOSTAL AT STA312+5 RBL 31; WL 208 I.A.W SRM 51-40-02-0G-0.; LOCATED AND DRILLED NEW INTERCOSTAL AT STA312+5 RBL 31; WL 208 P/N 141A5410-12 I.A.W SRM 51-40-05-0G-0 AND DWG 141A5400 AND OK TO INSTALL.INSTALLED NEW INTERCOSTAL AT STA312+5 RBL 31; WL 208 P/N 141A5410-12 I.A.W SRM 51-40-02-0G-0 AND DWG 141A5400.