What was found
BS 312 FRAME CRACKED AT I/B LOWER RADIUS ABOVE FED CUTOUT STR 6L / [01] VERIFIED THE APPLICABILITY OF SRM 51-10-02-0G-0;[02] CUT AND REMOVED THE DAMAGED AREA OF B/S 312 FRAME AT I/B LOWER RADIUS ABOVE FED CUTOUT STR 6L IAW SRM 51-10-02;[03] VERIFIED CORRECTIVE ACTION ENTRY 2.;[04] HFEC INSPECTED TRIMMED EDGE OF CUTOUT PER 737NDT PART 6 51-00-00 PROCEDURE 23. NO CRACKS FOUND. TOOL N500 IS000450 DUE 02/2023;[05] REFER TO EA 22-153-01433 SUMMARY REQUIREMENT; BARCODE: TTG8Q00CMVZN;[06] BS 312 FRAME CRACKED AT I/B LOWER RADIUS ABOVE FED CUTOUT STR 6L REPAIRED IAW EA 22-153-01433 (N7875A ? ATS (PAE) ? REPAIR - BS 312 FRAME UPPER CHORD CRACK DAMAGE AT LBL 33 BETWEEN S-5L AND S-6L);