What was found
EMERGENCY EXIT LIGHTS COME ON WHEN POWER IS OFF AND SWITCH IS ALSO OFF / [01] WHILE TROUBLESHOOTING DISCOVERED W4142-0032-22 WAS BROKEN CAUSING THE EMERG. EXIT LIGHTS TO COME ON WHEN POWER WAS OFF THE AIRCRAFT AND THE SWITCH WAS OFF. SPLICED WIRE W4142-0032-22 AS PER SWPM 20-30-12 AND PERFORMED GOOD OPERATIONAL CHECK AS PER AMM 33-51-06-960-805 STEP 4.E.(6).<BR><BR>CRIMPER ID:8546E<BR>S/N UNKNOWN<BR>DUE 07/2022<BR><BR>METER ID<BR>ID: ATS 1508<BR>S/N 32130497<BR>DUE 08/2022;[02] VERIFIED CORRECTIVE ACTION 1. VERIFIED GOOD OPERATIONAL TEST OF EMERGENCY LIGHTS PER AMM 33-51-06-960-805 STEP 4.E.(6).