What was found
DOOR 145AL (TOILET SERVICE DOOR) INNER SURFACE IS CORRODED AT SEVERAL LOCATIONS. / [01] REMOVED TOILET SERVICE DOOR 145AL PER AMM#52-49-07-000-801;[02] FOUND SRM 52-40-01-1A-4 TO BE APPLICABLE TO THIS REPAIR.<BR><BR>REMOVED DAMAGE IN MULTIPLE LOCATIONS LOCATED ON TOILET SERVICE DOOR INNER SURFACE. THE DEEPEST MEASURES 1.0' X 2.4' X 0.014' ORIGINAL THICKNESS IN POCKET IS 0.060' PER SRM 52-40-01-0I-4 TABLE 2. ITEM 1. FOUND TO BE IN LIMITS PER SRM 52-40-01-1A-4. USED CALIBRATED GAUGE ID: ATS2592 S/N:F01852.;[03] VERIFIED CORRECTIVE ACTION 2 AND MEASUREMENT TABLE LESS ITEM 5 AND 14.;[04] APPLIED CHEMICAL CONVERSION COATING PER SRM 51-20-01. APPLIED TWO LAYERS OF PRIMER PER SOPM 20-40-02.;[05] VERIFIED CORRECTIVE ACTION 4.;[06] APPLIED NEW PLACARDS PER AIPC 11-20-51-09 AND SOPM 20-10-14-400-801. INSTALLED TOILET SERVICE DOOR 145AL PER AMM 52-49-07-400-801. BONDING CHECK GOOD. USED CALIBRATED TOOL- BONDING METER ID: ATS1256 S/N:DC003960.;[07] VERIFIED CORRECTIVE ACTION 6