What was found
CRACK INDICATION FOUND ON RH HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT STATION 193.90 RIB; 16.500 INCH FROM FRONT SPAR; INBD SIDE OF RIB. CRACK LENGTH IS 0.750 INCH 2022-274485 / [01] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X12101V022240. DUE DATE: 27-JAN-23.;[02] PERFORMED REPAIR CATEGORY B FASTENER LOC. ON RH HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT STATION 193.90 ; 16.500 INCH FROM FRONT SPAR IAW B737-700 SRM 55-10-01-2R-11 REPAIR 11 FIGURE 204. SEE INDIVIDUAL SIGNOFFS BELOW;[03] PERFORMED REPAIR CATEGORY B FASTENER LOC. ON RH HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT STATION 193.90 ; 16.500 INCH FROM FRONT SPAR IAW B737-700 SRM 55-10-01-2R-11 REPAIR 11 FIGURE 204. SEE INDIVIDUAL SIGNOFFS BELOW<BR>RII