What was found
CORROSION FLOORBEAM EXISTING REPAIR LOCATED BS344 LBL7 AND WL208 AT FWD GALLEY AREA 2022-274603 / [01] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X1693P030456; CAL DUE DATE: 26-JAN-23;[02] TOOL USED EDDY CURRENT FLAW DETECTOR P/N: NORTEC 600D; S/N: 60009161631; DUE DATE: 03-DEC-22;[03] TOOL USED DIGITAL CALIPER P/N 500-193-30 S/N 0000293 DUE DATE 16-SEP-22;[04] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N:60007161486; DUE DATE: 06-DEC-22;[05] TOOL USED DIGITAL CALIPER P/N: 500-197-30 B20189511 DUE DATE: 16-SEP-22.;[06] TOOL USED: DIGITAL CALIPER;P/N:500-193-30; S/N:0000291; DUE DATE:16-SEP-22;[07] REPAIR FLOOR BEAM AT BSTA 344 AND BTW LBL 7 & RBL 11 EXISTING REPAIRS IAW EA# 22-153-01748;EA#22-153-01748-WIP1; EA#22-153-01748-WIP2; EA#22-153-01748-WIP3; EA#22-153-01748-WIP4 AND EA# 22-153-01748-WIP5; SEE INDIVIDUAL SIGN OFF BELOW;[08] REPAIR FLOORBEAM AT BSTA 344 AND BTW LBL 7 & RBL 11 EXISTING REPAIRS IAW EA# 22-153-01748;EA#22-153-01748-WIP1; EA#22-153-01748-WIP2; EA#22-153-01748-WIP3; EA#22-153-01748-WIP4 AND EA# 22-153-01748-WIP5;RII SEE INDIVIDUAL SIGN OFF BELOW