What was found
CABIN FLOOR PANEL 231YF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. <BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. RESIN (A110162); FABRIC (A24484); POTTING COMPOUND (A128121).;[02] APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-1 STEP 3 G-J. CURED AT 120 DEGREES (OVEN B0-06 EXP 8-13-22).;[03] REQUESTING OK TO BOND;[04] VERIFIED STEPS 1-3 AND OK TO BOND;[05] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES (AAR 30347 EXP 4-30-23). TAP TEST GOOD.;[06] REPAIRED 231YF UPPER SURFACE IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1.;[07] VERIFIED STEPS 5 AND 6; JOB COMPLETE; AUDIT C/W