What was found
CABIN FLOOR PANEL 241AF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. <BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. RESIN (A110162); FABRIC (A24484).;[02] REQUESTING OK TO BOND;[03] VERIFIED STEPS 1-2 AND OK TO BOND;[04] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES (AAR 30347 EXP 4-30-23). TAP TEST GOOD.;[05] REPAIRED CABIN FLOOR PANEL 241AF UPPER SURFACE IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1.;[06] VERIFIED STEPS 4 AND 5; JOB COMPLETE; AUDIT C/W