What was found
CRACKED LOWER L/H COMPOSITE BULKHEAD AT BS663 LBL46 WL164. / [01] REMOVED LOWER L/H COMPOSITE BULKHEAD (VAPOR BARRIER) BTW LBL8.- LBL70. BS 663.75 WL 164. IAW SRM 51-40-02.;[02] CRACKED LWR L/H COMPOSITE BULKHEAD AT B.S. 663 L.B.L. 46; W.L. 164; FOUND TO BE OUT LIMITS DUE TO NO ENTRIES ALLOWABLE DAMAGE IN SRM; IT WILL BE REPAIRABLE BY REPLACEMENT I.A.W. SRM 51-10-02-0G PAR. 9C.;[03] CORRECTED REFERENCE: CRACKED LWR L/H COMPOSITE BULKHEAD AT B.S. 663 L.B.L. 46; W. L. 164; FOUND TO BE OUT OF LIMITS BY DAMAGE LOCATION; WILL BE REPAIRABLE BY REPLACEMENT I.A.W. SRM 57-10-10-1A-2 PARAGRAPH 9C.;[04] CORRECTIVE ACTION 2 AND 3 ENTRIES AN ERROR. EVALUATED DAMAGED AT DISCREPANCY AREA AND FOUND OUT OF LIMITS DUE TO CRACKS ARE NOT PERMITTED AT DISCREPANCY AREA I.A.W. SRM 57-10-10-1A-2 ZONE 1 FIG 101 DETAIL B.;[05] VERIFIED CORRECTIVE ACTION 4;[06] VERIFIED MEASUREMENT TABLE;[07] PARTIALLY COMPLETED STEP 6;[08] RECEIVED NEW LH VAPOR BARRIER P/N ATSHFAB -101-201 LOCATED AND DRILLED IAW SRM 51-40-05-0G-0 AND DWG#111A1001 OK TO INSTALL LOWER CHORD ON STEP-6;[18] INSTALLED L/H VAPOR BARRIER IAW SRM 51-40-02; DWGS # 111A100; 111A1001 AND COMPLETED STEPS 1;2;3;4;5;6;7.;