What was found
AFT CABIN FLOOR PANEL 242UF HAS PULLED THROUGH INSERTS / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO INSERT LOCATION TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED ALL DAMAGED INSERTS; REMOVED DAMAGED SKIN AND CORE AROUND INSERT LOCATION ON AFT EDGE; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-6 PARA 3A-E.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-6.;[03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2 COMPLETED.;[04] FABRICATED CORE PLUG FROM BMS 8-124;C4;T5;GR9 LOT#1287137 AND UPPER SURFACE REPAIR PLIES FROM BMS 9-3H2 LOT#1493221-1 IAW SRM 53-00-50-2R-6 PARA 3F-G.<BR>OK TO INSTALL.[11] INSTALLED LOWER REPAIR PLIES USING BMS 8-201TY4 LOT#AK1KP9161K; VACUUM BAGGED; LEAK CHECK GOOD IAW SRM 53-00-50-2R-6 PARA 3K-L.<BR>USED VACUUM GAUGE ID:E11543 CAL DUE 08/2022;