What was found
CORROSION ON FWD ENTRY DOOR MOP SEAL AT LBL 55 BS 294+8; BS 312; BS 312+4; BS 344+1; BS 344+11. / [01] VERIFIED APPLICABILITY OF SRM 53-10-15-01-1 FOR IDENTIFICATION AND SRM 53-10-15-1A-1 FOR ALLOWABLE LIMIT;[02] PARTIALLY COMPLETED STEPS 1-5;[03] VERIFIED CORRECTIVE ACTIONS #1 AND #2<BR>STEPS 1-5 COMPLETE;[04] REMOVED FWD ENTRY DOOR MOP SEAL AT LBL 55 BS277 - BS360 PER SRM 51-40-02-0G-0;[05] LOCATED AND DRILLED DOOR MOP SEAL ITEM 654A0004-1073 LOT 1491614-1 IAW SRM 51-40-05-OG-0 AND DWG 141A8110.<BR>REQUIRED OK TO INSTALL.;[06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON DRILLED UP HOLES IAW SRM 51-20-01 AND SOPM 20-41-02.<BR>REQUIRED OK TO INSTALL.;[07] VERIFIED CORRECTIVE ACTION 4-6 OK TO INSTALL;[08] INSTALLED DOOR MOP SEAL ITEM 654A0004-1073 LOT 1491614-1 IAW SRM 51-40-02-OG-0 AND DWG 141A8110.;[09] VERIFIED CORRECTIVE ACTION 8.;[10] VERIFIED MEASUREMENT TABLE. WORKSCOPE COMPLETE.