What was found
CORROSION ON FWD ENTRY DOOR MOP SEAL ATTACH ANGLE AT LBL 58 BS 312+4-312+10; BS 328+7. / [01] VERIFIED APPLICABILITY OF SRM 53-10-15-01-1 FOR IDENTIFICATION AND SRM 53-10-15-1A-1 FOR ALLOWABLE LIMIT;[02] PARTIALLY COMPLETED STEPS 1-3;[03] STEPS 1-3 COMPLETE;[04] REMOVED FWD ENTRY DOOR MOP SEAL ATTACH ANGLE AT LBL 58 BS 312+4-312+10; BS 344; LBL 58 PER SRM 51-40-02-0G-0;[05] RECEIVED NEW FWD ENTRY DOOR MOPSILL Z - ANGLE ITEM 141A8112-20; PO NUMBER 786153. LOCATED AND DRILLED IAW SRM 51-40-05-OG-0 DWG 141A8110.<BR>REQUIRE OK TO INSTALL.;[06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON DRILLED UP HOLES IAW SRM 51-20-01 AND SOPM 20-41-02.<BR>REQUIRED OK TO INSTALL.;[07] VERIFIED CORRECTIVE ACTION 4-6 OK TO INSTALL;[08] INSTALLED FWD ENTRY DOOR MOPSILL Z - ANGLE IAW SRM 51-40-02-0G-0 AND DWG 141A8110.;[09] VERIFIED CORRECTIVE ACTION 8 INSTALLATION;[10] TASK COMPLETE. VERIFIED MEASUREMENT TABLE