What was found
CORROSION ON AFT CARGO BAY INTERCOSTAL AT RBL 19 BS 767+6. / [01] VERIFIED APPLICABILITY PER SRM 53-60-15-1A-1<BR>REMOVED CORROSION ON AFT CARGO BAY INTERCOSTAL RBL 19 BS 767+6. REWORKED AREA L=3';W=1.3';D=0.009' ORIGINAL THICKNESS 0.050'. FOUND TO BE OUT OF LIMIT IAW SRM 53-60-15-1A-1 STEP4G(2)(B) FIG 103.<BR>TOOL USED ID:ATS1672<BR>S/N:65092939<BR>DUE:03/2023;[02] UPDATED MEASUREMENTS;[03] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE.;[04] REMOVED ON AFT CARGO BAY INTERCOSTAL AT RBL 19 BS 767 TO BS 787 IAW SRM 51-40-02;[05] RECEIVED ON AFT CARGO BAY INTERCOSTAL NEW AT RBL 19 BS 767 TO BS 787 ITEM 146A8123-19 PO#865464. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 146A8123.<BR>OK TO INSTALL;[06] PART NUMBER INFO;[07] VERIFIED CORRECTIVE ACTIONS 4-6. VERIFIED P/N UPDATE IN MEASUREMENT TABLE; OK TO INSTALL GIVEN;[08] INSTALLED ON AFT CARGO BAY INTERCOSTAL AT RBL 19 BS 767 TO BS 787 IAW SRM 51-40-02 AND DWG146A0081;[09] VERIFIED CORRECTIVE ACTION 8;[10] VERIFIED ALL WORK COMPLETE