What was found
CRACKED FLOOR SUPPORT AT STA 539; LBL 1; WL 207.5 / [01] ROMOVED PASSENGER CABIN FLOOR PANEL 231UF IAW AMM 53-21-00-000-801.;[02] REMOVED CRACKED FLOOR SUPPORT AT STA 539; LBL1-LBL24.5 WL 207.5 IAW SRM 51-40-02-0G-0.;[03] LOCATED AND DRILLED NEW FLOOR SUPPORT AT STA 539 LBL1-LBL24.5 WL 207.5 IAW SRM 51-40-05-0G-0. OK TO INSTALL.;[04] VERIFIED CORRECTIVE ACTION 1-3 COMPLETED AND OK TO INSTALL; AND VERIFIED MEASUREMENT TABLE.;[05] INSTALLED NEW FLOOR SUPPORT AT STA 539 LBL1-LBL24.5 WL 207.5 IAW SRM 51-40-02-0G-0. OK TO INSTALL FLOOR PANEL 231UF.;[06] RII VERIFIED CORRECTIVE ACTION 5 COMPLETED AND OK TO CLOSE PANEL COMPLETED;[07] CLOSED PASSENGER FLOOR PANEL 231UF IAW AMM 53-21-00-400-801. USING SCREW GUN ID: ATS547 S/N: UNKNOWN DATE 05/2022 DUE 02/2023.;[08] VERIFIED CORRECTIVE ACTION 7 COMPLETED