What was found
CRACK ON FWD CARGO BAY GUSSET AT BS 500D L/H STRINGER 19. / [01] REMOVED GUSSET AT FCB BS 500D L/H STR 19 IAW SRM 51-40-02;[02] NOT FOUND ALLOWABLE DAMAGE LIMITS ON SRM ; GUSSET MUST BE REPLACED IAW SRM 51-10-02 PARAGRAPH 9;[03] LOCATED AND DRILLED NEW GUSSET AT B/S 500D STR 19 L/H LOT # 1480476-3 IAW SRM 51-40-05 AND DWG 143A7902 REV:E <BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION ITEM 3 DRILL UP OF NEW GUSSET. <BR>OKAY TO INSTALL GUSSET.;[05] INSTALLED NEW GUSSET AT B/S 500D STR 19 L/H IAW SRM 51-40-02 AND DWG 143A7902 REV:E;[06] VERIFIED CORRECTIVE ACTION STEP 5.;[07] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.