What was found
FWD CARGO FLOOR L/H TRANSITION ANGLE STA. 500A-500C HAS CORROSION AROUND FASTENER HOLES. / [01] REMOVED CORROSION PER SRM 53-00-53-1A-2.;[02] REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2.;[03] 2. ABUYE KEBEDE (TECHNICIAN); 01-AUG-2022 07:46 UTC<BR>REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMIT PER SRM 53-00-53-1A-2. VERIFIED.;[04] CUT AND REMOVED THE DAMAGED PART OF L/H TRANSITION ANGLE PER SRM 53-00-53-2R-5.;[05] 4. ABUYE KEBEDE (TECHNICIAN); 02-AUG-2022 09:18 UTC<BR>CUT AND REMOVED THE DAMAGED PART OF L/H TRANSITION ANGLE PER SRM 53-00-53-2R-5.<BR>C/W RII INSPECTION.;[06] OK TO INSTALL;[07] INSTALLED REPAIR PER SRM 53-00-53-2R-5;[08] INSTALLED BONDED NUT PLATES PER SRM 51-40-10-2R-0;[09] INSPECTED INSTALLED REPAIR;[10] WORK PERFORMED CERTIFICATION INDEPENDENT INSPECTION<BR>1. HERNANDEZ; ANDY (COMPLETE)<BR>10-AUG-2022 02:14:08<BR>ACCOMPISHED PUSH TEST ON BONDED NUT PLATES FWD CARGO L/H TRANSITION ANGLE REPAIR ( YELLOW 70 IN LBS.) IAW SRM 51-40-10-2R01.<BR>C/W INSPECTION.;[11] VERIFIED ALL WORK STEPS COMPLETED AND SIGNED OFF. EA GENERAL SELECTED AS REFERENCE AS CALLED OUT ON EA.;[12] 11. ERIC GRASKEY (TECHNICIAN); 10-AUG-2022 06:19 UTC<BR>VERIFIED ALL WORK STEPS COMPLETED AND SIGNED OFF. EA GENERAL SELECTED AS REFERENCE AS CALLED OUT ON EA.<BR>C/W INSPECTION.