What was found
FWD CARGO FLOOR L/H TRANSITION ANGLE STA. 500C (+12) HAS CORROSION AROUND FASTENER HOLE. / [01] REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] 1. ABUYE KEBEDE (TECHNICIAN); 01-AUG-2022 08:17 UTC<BR>REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. VERIFIED.;[03] CUT AND REMOVED DAMAGED L/H TRANSITION ANGLE PER SRM 53-00-53-2R-5.;[04] 3. ABUYE KEBEDE (TECHNICIAN); 02-AUG-2022 09:24 UTC<BR>CUT AND REMOVED DAMAGED L/H TRANSITION ANGLE PER SRM 53-00-53-2R-5.<BR>C/W RII INSPECTION.;[05] OK TO INSTALL;[06] INSTALLED REPAIR PER SRM 53-00-53-2R-5;[07] INSTALLED BONDED NUT PLATES PER SRM 51-40-10-2R-0;[08] INSPECTED INSTALLED REPAIR;[09] WORK PERFORMED CERTIFICATION INDEPENDENT INSPECTION<BR>1. HERNANDEZ; ANDY (COMPLETE)<BR>10-AUG-2022 08:05:49<BR>ACCOMPISHED PUSH TEST ON BONDED NUT PLATES FWD CARGO L/H TRANSITION ANGLE REPAIR ( YELLOW 70 IN LBS.) IAW SRM 51-40-10-2R01.<BR>C/W INSPECTION.;[10] VERIFIED ALL STEPS COMPLETED AND SIGNED OFF.;[11] 10. ERIC GRASKEY (TECHNICIAN); 10-AUG-2022 08:13 UTC<BR>VERIFIED ALL STEPS COMPLETED AND SIGNED OFF.<BR>C/W INSPECTION.