What was found
CRACK ANGLE LOCATED BS695 AT BL0 AT CENTER WING BOX 2022-365481 / [01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-23; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112820025; DUE DATE: 01-FEB-23.;[02] REPLACED ANGLE LOC. BS695 AT BL0 AT CENTER WING BOX. IAW B737-700 SRM 51-40-02 AND DWG# 273A9110 SHEET 6 REV A AND SRM 51-10-02 PARAGRAPH 9 MATERIAL USED: BAC1490-2883 (7075T0-0.050 INCH) PO: 2022 110625;[03] CORRECTIVE STEP 2<BR>REPLACED ANGLE LOC. BS695 AT BL0 AT CENTER WING BOX. IAW B737-700 SRM 51-40-02 AND DWG# 273A9110 SHEET 6 REV A AND SRM 51-10-02 PARAGRAPH 9 MATERIAL USED: BAC1490-2883 (7075T0-0.050 INCH) PO: 2022 110625. SEE INDIVIDUAL SIGNSOFF BELOW.;[04] REPLACED ANGLE LOC. BS695 AT BL0 AT CENTER WING BOX. IAW B737-700 SRM 51-40-02 AND DWG# 273A9110 SHEET 6 REV A AND SRM 51-10-02 PARAGRAPH 9 MATERIAL USED: BAC1490-2883 (7075T0-0.050 INCH) PO: 2022 110625. SEE INDIVIDUAL SIGNSOFF BELOW. RII