What was found
ANOMALY ON EXTERNAL FUSELAGE SKIN S-16L TO S-19L BS787 - BS827. MARKED. / [01] EVALUATED ANOMALIES ON FUSELAGE SKIN AT BS 787+14.5 6.5'BELOW STR 19L D=.0006'; BS 787+12 1'BELOW STR 18L D=.0005'; BS 787+11 6'BELOW STR 17L D=.001'; BS 807+6 6'BELOW STR 18L D=.0015'; BS 807+4.5 5'BELOW STR 17L D=.0003'; BS 827+8 1.5'BELOW STR 18L D=.0002'; BS 827+11 5.5'BELOW STR 17L D=.0002'; BS 827+4 4'BELOW STR 16L D=.001' IAW SRM 53-00-01-1A-1;[02] DEPTH MEASUREMENTS MISSING CAL TOOL REQUIREMENTS.;[03] OPTICAL MICROMETER USED ID:IS000637 S/N:9761 DUE:02/2023<BR>DIAL DEPTH GAUGE USED ID:ATS2677 S/N:UNKNOWN DUE:11/2022.<BR>TOOLING USED FOR CORRECTIVE ACTION 1;[04] VERIFIED CORRECTIVE ACTION ITEM 3;[05] SKIN PANEL TO BE REPLACED ON FAULT TTG8Q00DE55B;[06] VERIFIED CORRECTIVE ACTION 5