What was found
CABIN FLOOR PANEL 242TF HAS FRAYED UPPER SURFACE PLIES / [01] IDENTIFIED MATERIAL IAW SRM 53-00-50-0I-1 TABLE 6 FIG 6.<BR>DAMAGE TO UPPER SURFACE SKIN PLIES IS OUT OF ALLOWALBE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B<BR>REPAIR TO BE ACCOMPLISHED IAW SRM 53-00-50-2R-1<BR><BR>REMOVED 15 THROUGH INSERTS TO FACILITATE REPAIR.<BR>REMOVED DAMAGE AND CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 4C-F;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] VERIFIED CORRECTIVE ACTION ITEMS 1 AND 2.;[04] FABRICATED REPAIR PLIES USING BMS 9-3 LOT#1493221-1 IAW SRM 53-00-50-2R-1 PARA 3.K<BR>OK TO INSTALL.;[05] INSPECTED AND VERIFIED CORRECTIVE ACTION 4. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-1.;[06] INSTALLED REPAIR PLIES USING BMS 8-201 TY4 LOT#1496781-4; VACUUM BAGGED; LEAK CHECK GOOD USING VACUUM GAUGE ID:ATS2107 DUE:09/2022 IAW SRM 53-00-50-2R-1 PARA 3.K&L.;[07] INSPECTED AND VERIFIED CORRECTIVE ACTION 6. 5X5 LEAK CHECK PASSED PER SRM 53-00-50-2R-1.;[08] CURED REPAIR PLIES USING THERMOMETER ID:ATS2208 CALIBRATION DUE DATE:10/2022; UNBAGGED; LOCATED; DRILLED; AND UPSIZED ALL INSERT LOCATIONS COVERED BY REPAIRS; INSTALLED 15EA THROUGH INSERTS USING BMS 5-107 LOT#AK1KP9159K; CURED IAW SRM 53-00-50-2R-1 PAR 3M(1);N AND DWG 147A5810-94.<BR><BR>COMPLETED SRM REPAIR 53-00-50-2R-1.;[09] VERIFIED CORRECTIVE ACTION 8;[10] ADDED CURE SHEETS TO THIS FAULT RECORD.;[11] FINAL INSPECTION. JOB COMPLETE PER SRM 53-00-50-2R-1