What was found
CABIN FLOOR PANEL 242RF UPPER SURFACE PLIES FRAYED / CRACKED SKIN PLIES AND DAMAGED CORE.<BR>DAMAGE NOTED IS OUT OF ALLOWALBE DAMAGE LIMITS REMOVED DAMAGE AND CLEANED REPAIR AREAS; OK TO POT EXPOSED CORE IAW SRM 53-00-50-2R-1 PARA 4C-F;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;VERIFIED CORRECTIVE ACTION ITEMS 1 AND 2.;[04] APPLIED POTTING BMS5-28 TYPE 19 LOT#AK2DP3091K TO EXPOSED CORE IAW SRM 53-00-50-2R-1 PARA 4G;[05] CURED POTTING USING THERMOMETER ID:ATS2208 DUE:10/2022; SANDED TILL SMOOTH; CLEANED REPAIR AREA; AND FABRICATED REPAIR PLIES USING BMS 9-3 LOT#1493221-1 IAW SRM 53-00-50-2R-1 PARA 3.H-K.<BR>OK TO INSTALL.;[06] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 4 AND 5. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-1.;[07] INSTALLED REPAIR PLIES USING BMS 8-201 TY4 LOT#1496781-4; VACUUM BAGGED; LEAK CHECK GOOD USING VACUUM GAUGE ID:ATS2107 DUE:09/2022 IAW SRM 53-00-50-2R-1 PARA 3.K&LCURED REPAIR PLIES USING THERMOMETER ID:ATS2208 CALIBRATION DUE DATE:10/2022; UNBAGGED; LOCATED; DRILLED; AND UPSIZED ALL INSERT LOCATIONS COVERED BY REPAIRS; INSTALLED 7EA THROUGH INSERTS USING BMS 5-107 LOT#AK1KP9159K; CURED IAW SRM 53-00-50-2R-1 PAR 3M(1);N AND DWG 147A5810-2.<BR><BR>COMPLETED SRM REPAIR 53-00-50-2R-1.ADDED CURE SHEETS TO THIS FAULT RECORD.FINAL INSPECTION. REPAIR COMPLETE PER SRM 53-00-50-2R-1.;[13] FINAL INSPECTION. REPAIR COMPLETE PER SRM 53-00-50-2R-1.<BR><BR>VERIFIED MEASUREMENTS TABLE