What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727E; BS 727E+10; BS 727E+18; BS 747+2; BS 747+6; BS 747+14. / [01] ENTERED MEASUREMENTS.;[02] SRM 53-00-53-1A-2 IS EFFECTIVE FOR THIS EVALUATION.<BR>REMOVED CORROSION IAW SRM 51-10-02-0G-0.<BR>AREAS MEASURE:<BR><BR>727E; 1.00'L X 1.00'W X 0.007'D<BR><BR>727E+10; 1.20'L X 1.00'W X 0.008'D<BR><BR>727E+18 2.40'L X 1.10'W X 0.009'D<BR><BR>747+2 2.50'L X 1.40'W X 0.009'D<BR><BR>747+6 1.90'L X 1.20'W X 0.008'D<BR><BR>747+14 2.30'L X 1.00'W X 0.011'D<BR><BR>ORIGINAL MATERIAL THICKNESS - 0.040'<BR>REMAINING MATERIAL - 0.029'<BR>DIAL DEPTH GAGE: ATS401; S/N UNKNOWN; CAL DUE 10/2022;[03] CCORROSION FOUND TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-53-1A-2; 4A(2)(A) FIGURE 103; DETAIL E.<BR>REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0; STEP 9.;[04] VERIFIED ACTION #1-3;[05] REMOVED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM BS 727+4 TO BS 767 ; RBL 21 IAW SRM 51-40-02-0G-0;[06] FABRICATED; LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT AND SPLICE FROM BAC1496-377 7075-T62 ; LOT# 1500263-1 ; BS 727+4 TO BS 767 ; RBL 21 IAW SRM 51-40-05-0G-0; DWG 146A7502; ID:0026. REV:-; APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802; OK TO APPLY PRIMER;[17] UPGRADED REPAIR TYPE TO MAJOR DUE TO REPAIR. SPLICE INSTALLED.;[18] VERIFIED TABLE MEASUREMENT REPAIR TYPE UPGRADE;[19] VERIFIED CORRECTIVE ACTION 17 AND 18;[20] VERIFIED MEASUREMENT TABLE