What was found
CRACKED INTERCOSTAL AT STA 312+5 & STA 312+11; WL 208; RBL 31. / [01] NO ALLOWABLE LIMITS FOUND ON SRM REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR.9.C;[02] REMOVED INTERCOSTAL LOCATED BS312-BS328 RBL31 WL208 I.A.W SRM 51-40-02-0G-0;[03] LOCATED AND DRILLED INTERCOSTAL LOCATED BS312-BS328 RBL31 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 141A5400 OK TO INSTALL;[04] INSPECTED ACTION 1-3; VERIFIED MEASUREMENT TABLE. OK TO INSTALL;[05] INSTALLED INTERCOSTAL LOCATED BS312-BS328 RBL31 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 141A5400 COMPLETED REMOVED AND REPLACED TASK;[06] INSPECTED ACTION 5;[07] INSPECTION COMPLETE