What was found
CORROSION ON INTERCOSTAL FROM STA 312 TO 328; WL 208; LBL 12. / [01] REMOVED PANEL BREAK AT STA 312 TO 328 WL 208 LBL 12 IAW SRM 51-40-02<BR><BR>REMOVED CORROSION ON PANEL BREAK BS 314 IN L=2' X W=2' X D=0.40' FROM ORIGINAL TICKNESS OF 0.80' FOUND TO BE OUT OF LIMITS.<BR><BR>REMOVED CORROSION ON PANEL BREAK BS 326 IN L=2' X W=2' X D=0.40' FROM ORIGINAL TICKNESS OF 0.80' FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1 PAR 4F E.<BR><BR>USED TOOL :<BR>ID:LS000459 ; S/N: 67127987 ; DATE:01/2022 ; DUE: 01/2023.;[02] PANEL BREAK IT IS OUT OF LIMITS DUE TO NO LIMITS GIVEN IN THE SRM BY REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[03] VERIFIED CORRECTIVE ACTION #2.;[04] LOCATED AND DRILLED NEW INTERCOSTAL FROM BS 312 TO 328 WL 208 LBL 12 IAW SRM 51-4O-05-0G- 0 ; AND OK TO INTALL;[05] CERTIFY;[06] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.;[07] INTALLED NEW INTERCOSTAL FROM BS 312 TO 328; WL 208; LBL 12. IAW SRM 51-40-02-0G-0 AND DWG #141A5400;[08] UPDATED P/N AND PART REQUIREMENT;[09] CERTIFY;[10] UPDATED CHART;[11] CERTIFY;[12] VERIFIED CORRECTIVE ACTION 7.;[13] VERIFIED MEASUREMENT TABLE.