What was found
DOT A-24-3 CENTER CABIN FLOOR BOARD PANEL 242AF HAS PULLED COMPOSITE FIBERS ON UPPER SURFACE. / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE LENGTH OF BOARD. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP 3 A; C; E-F.<BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. RESIN (A141927); POTTING COMPOUND (E125915); FABRIC (A10269).<BR><BR>REQUEST OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 250 DEGREES (OVEN B0-06 EXP 11-8-22). TAP TEST GOOD.;[04] REPAIRED CENTER CABIN FLOOR BOARD PANEL 242AF UPPER SURFACE ALONG LENGTH OF BOARD IAW SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-0 REPAIR GENERAL.;[05] VERIFIED STEP 3-4