What was found
DOT A-24-21 MID CABIN FLOOR BOARD 241AF HAS PULLED COMPOSITE FIBERS ON TOP SIDE OF PANEL. / [01] EVALUATED AND FOUND PULLED FIBERS AND A PUNCTURE ON UPPER SURFACE ARE REPAIRABLE IAW SRM 53-00-50-2R-0 REPAIR GENERAL TABLE 201 REPAIR 1<BR>CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50-2R-1 STEPS 3A;C;D;E;F.<BR>VERIFIED REPAIR MATERIALS AS POTTING COMPOUND--EPOCAST1619(A133227); GLASS CLOTH--BMS9-3TYH3(A10269); RESIN--EPOCAST50A1/9816(A147958) IAW SRM 53-00-50-2R-1 TABLE 201.<BR>APPLIED POTTING COMPOUND TO PUNCTURE IAW SRM 53-00-50-2R-1 STEPS 3G-J. CURED WITH HEAT LAMP AND DIGITAL THERMOMETER(AAR 30347 DUE 4-30-23)<BR>NEED OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEPS 3K-M. TAP TEST GOOD. CURED WITH HEAT LAMP AND DIGITAL THERMOMETER (AAR30347 DUE 4-30-23);[04] REPAIRED DAMAGE TO UPPER SURFACE OF FLOOR BOARD 241AF IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1 REPAIR 1. TAP TEST GOOD. TOOLING--AAR30347 DUE 4-30-23;[05] VERIFIED STEPS 3-4