What was found
DOT A-24-23 MID CABIN FLOOR BOARD 232SF HAS PULLED COMPOSITE FIBERS ON TOP SIDE OF PANEL. / [01] EVALUATED AND FOUND PULLED FIBERS ON UPPER SURFACE TO BE REPAIRABLE IAW SRM 53-00-50-2R-0 REPAIR GENERAL TABLE 201 REPAIR 1<BR>CLEANED AND PREPPED UPPER SURFACE IAW SRM 53-00-50-2R-1 STEP 3 A;C;E;F<BR>VERIFIED REPAIR MATERIALS AS GLASS CLOTH--BMS 9-3TYH3(A10269); RESIN--EPOCAST50A1/9816 (A147958) IAW SRM 53-00-50-2R-1 TABLE 201<BR>NEED OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEPS 3K-M. TAP TEST GOOD. CURED WITH HEAT LAMP AND DIGITAL THERMOMETER (AAR30347 DUE 4-30-23);[04] REPAIRED DAMAGE TO UPPER SURFACE OF FLOOR BOARD 232SF IAW SRM 53-00-50-2R-0 REPAIR GENERAL AND SRM 53-00-50-2R-1 REPAIR 1. TAP TEST GOOD. TOOLING--AAR30347 DUE 4-30-23;[05] VERIFIED STEPS 3-4