What was found
DOT A-24-28 MID CABIN FLOOR BOARD 231YF HAS PULLED COMPOSITE FIBERS ON TOP SIDE OF PANEL. / [01] EVALUATED AND FOUND MISSING FIBERS ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP 3 A; C; E-F.<BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. RESIN (A147728); FABRIC (A10269).<BR><BR>REQUEST OK TO BOND;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR PLIES IAW B737 SRM 53-00-50-2R-1 PAR 3 STEPS K;L;AND M. TAP TEST GOOD. OVEN B0-06 CAL DUE 11/8/22.;[04] REPAIRED MID CABIN FLOOR BOARD 231YF IAW B737 SRM 53-00-50-2R-1 PAR 3; OVEN B0-06 CAL DUE 11/8/22.;[05] VERIFIED STEPS 3-4