What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE BS 344 TO BS 360 BL 0 AT FWD GALLEY AREA 2022-517129 / [01] REPLACED INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TAND BS 360 AT BL 0 FWD GALLEY AREA IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 141A5400 SH 32 REV -<BR>SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TAND BS 360 AT BL 0 FWD GALLEY AREA IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 141A5400 SH 32 REV - RII VERIFIED