What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE BS 312 TO BS 328 LBL 45 AT FWD GALLEY AREA 2022-517132 / [01] REPLACED WEB INTERCOSTAL ON FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 AT LBL 45 FWD GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV -.<BR>SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED WEB INTERCOSTAL ON FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 AT LBL 45 FWD GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV -. <BR>SEE INDIVIDUAL SIGN OFF BELOW.<BR>ITEM RII