What was found
CRACK INSPAR RIB LOCATED STAB STA 129.50 AND 18 INCH FROM FRONT SPAR LT HORIZONTAL STAB 2022-576071 / [01] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022240; CAL DUE DATE: 27-JAN-23;[02] TOOL EDDY CURRENT USED P/N: NORTEC 600D S/N: 210138503 AND DUE DATE: 19-MAY-23.;[03] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 01-FEB-23; TEMPERATURE CONTROLLER P/N: 112820025; DUE DATE: 01-FEB-23.;[04] PERFORMED REPAIR ON INSPAR RIB LOCATED STAB STA 129.50 AND 18 INCH FROM FRONT SPAR LT HORIZONTAL STAB IAW EA #22-155-03137 [TTG8Q00FU9HP]; EA# 22-155-03137-WIP1 [TTG8Q00FMTB7] AND EA# 22-155-03137-WIP2 [TTG8Q00FP0KV];[05] PERFORMED REPAIR ON INSPAR RIB LOCATED STAB STA 129.50 AND 18 INCH FROM FRONT SPAR LT HORIZONTAL STAB IAW EA #22-155-03137 [TTG8Q00FU9HP]; EA# 22-155-03137-WIP1 [TTG8Q00FMTB7] AND EA# 22-155-03137-WIP2 [TTG8Q00FP0KV]<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[06] TASK COMPLETED; RII <BR><BR>SEE INDIVIDUAL SIGN OFFS BELOW