CRACKED INTERCOSTAL AT STA 312+4 AND 312+10; RBL 31; WL 208. / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-01-2 FOR IDENTIFICATION AND SRM 53-30-53-1A-1 FOR ALLOWABLE LIMIT;[02] DAMAGE FOUND AT INTERCOSTAL BS 312+4 ; RBL 31; WL 208 P/N 141A5410-12 1' LONG; FOUND TO BE OUT OF LIMIT IAW SRM 53-30-53-1A-1 DET.4A(1); FIG 103;[03] VERIFIED CORRECTIVE ACTIONS 1; #2.;[04] REMOVED FWD CABIN INTERCOSTAL BS 312 TO BS 328 RBL 31 IAW SRM 51-40-02 ; LOCATED AND DRILLED NEW INTERCOSTAL IAW SRM 51-40-05 AND DWG # 141A5400 ; OK TO INSTALL;[05] INSTALLED NEW FWD CABIN INTERCOSTAL BS 312 TO BS 328 RBL 31 IAW SRM 51-40-02 AND DWG # 141A5400 .;[06] INSPECTED ACTION 4; OK TO INSTALL GIVEN PRIOR TO ACTION 5;[07] VERIFIED CORRECTIVE ACTION 5;;[08] VERIFIED MEASUREMENT TABLE