What was found
PANEL 561AB HAS SEVERAL PULLED FASTENER HOLE ON AFT END (MARKED) / VALIDATED REPAIR PER SRM 51-70-04-2R-9;[03] STARTED DAMAGE REMOVAL PER SRM 51-70-04-2R-9 PARA 4 STEPS A & B .;[04] COMPLETED DAMAGE REMOVAL CURED THE RESIN MIXTURE & PERFORMED THE SURFACE PREPARATION STEPS IAW SRM 51-70-04-2R-9 PARA 4 STEPS E-I PER GENERAL REPAIR SRM 51-70-04-2R-0 FIGURE 214 PAGE 39. REF CAL TOOL THERMOMETER ID ATS883 SN 15112530 CAL DUE 10/2022 .;[08] USING BMS9-3 STYLE 1581 GLASS LOT 1502472-1 & BMS8-301/EA9390 RESIN LOT JH1HAA6331 FABRICATED THE REPAIR PLIES ; LAID UP THE REPAIR ;VACUUM BAGGED LEAK CHECKED ;THEN SET TO CURE IAW SRM 51-70-04-2R-9 PARA 4 STEPS J-L .;[09] COMPLETED REPAIR PLY CURE PROCEDURE IAW SRM 51-70-04-2R-9 PARA 4 STEP M. PER GENERAL REPAIR SRM 51-70-04-2R-0 FIGURE 214 PAGE 39 REF CAL TOOL HOT BONDER ID ATS2802 CAL DUE 10/2023 .;[10] VERIFIED CORRECTIVE ACTIONS 6-9;[11] REQUEST POST REPAIR EXAMINATION IAW SRM 51-70-04-2R-9 PARA 4 . O;[12] UT INSPECTED POST CURE IAW 737 NDTM PART 4 51-00-02. <BR>NO DISBONDS NOTED.<BR>EQUIP USED: <BR>-EPOCH 650 ID: ATS2031 CAL DUE: 03/23;[13] RESTORE THE CONDUCTIVE COATING : APPLIED BMS10-21 TYPE III CONDUCTIVE COATING ; CURED THEN TESTED GOOD IAW AMM 51-21-71-370-801 PARA 3. D . STEPS 1-4 & 7 (B) . REF CAL TOOL MULTIMETER ID ATS1658 CAL DUE 03/2023;[