What was found
CORROSION ON FLOOR SUPPORT AT AFT PASSENGER CABIN BS947+9 RBL8. MARKED. / [01] REMOVED CORROSION ON FLOOR SUPPORT AT AFT PASSENGER CABIN BS947+9 RBL 8 WL 208.1. IAW SRM 51-10-02. REWORKED AREA L=4'X W=2' MAX MATERIAL LOSS 0.009' REMAINING THICKNESS IS 0.065' ORIGINAL THICHNESS IS 0.074' PER DWG 147A5765.- FOUND TO BE OUT OF LIMITS AW SRM 53-70-51-1A-1 ALLOWABE DAMAGE 4 (C) 2(A). <BR>TOOL ID USED: ATS 1671<BR>S/N: 65093024<BR>DATE: 01/2022<BR>DUE: 01/2023;[02] VERIFIED APPLICABILITY OF SRM 53-70-51-1A-1 FOR ALLOWABLE DAMAGE;[03] RECIVED NEW FLOOR SUPPORT ITEM:147A5765-22;LOCATED AND DRILLED NEW FLOOR SUPPORT AT AFT PASSENGER CABIN BS947+9 RBL8 WL 208.1 ; IAW 737-700 SRM 51-40-05-0G-0 DWG 147A5765; REV: A. OK TO INTALL.;[04] INSPECTED ACTION 1-3; MEASUREMENT TABLE INCORRECT REPAIR TYPE IS NOT MAJOR FOR PART REPLACEMENT. OK TO INSTALL;[05] CORRECTED MEASUREMENT TABLE ; STEP 22 REPAIR TYPE;[06] INSTALLED AFT PASSENGER CABIN FLOOR SUPPORT BS 947+9; RBL 8; WL 208; IAW SRM 51-40-02-0G-0 AND DWG# 147A5760 REV:B;[07] VERIFIED CORRECTIVE ACTION #6<BR>VERIFIED MEASUREMENTS