What was found
CORROSION ON TENSION STRAP AT AFT PASSENGER CABIN RBL3 BS1016+6 - BS1016+14. MARKED. / [01] SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 IS APPLICABLE TO THIS A/C<BR>REMOVED CORROSION ON PASSENGER CABIN FLOOR AFT STRAP AT RBL 3 BS 1016+6 TO BS1016+14 WL 208.1 IAW SRM 51-10-02. REWORKED AREA L=3'XW=1'MAX MATERIAL LOSS 0.004' REMAINING THICKNESS IS 0.067' ORIGINAL THICHNESS IS 0.071' PER DWG 147A5744.- WAS FOUND IN THE LIMITS AW SRM 53-70-51-1A-1 ALLOWABE DAMAGE 1. OK TO TREAT AND PRIME THE REWORKED AREA<BR>TOOL ID USED: ATS 1671<BR>S/N: 65093024<BR>DATE: 01/2022<BR>DUE: 01/2023;[02] VERIFIED APPLICABILITY OF SRM 53-70-51-1A-1 FOR ALLOWABLE DAMAGE;[03] VERIFIED CORRECTIVE ACTIONS #1 AND #2<BR>MEASUREMENT TABLE VERIFIED <BR>OK TO TREAT AND PRIME THE REWORKED AREA GIVEN;[04] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON TENSION STRAP AT AFT PASSENGER CABIN RBL3 BS1016+6 - BS1016+14 WL 208.1 IAW 737-700; AMM 51-21-72-370-804; AMM 51-21-41-370-802;[05] CORRECTED DWG 147A5744 REV: E;[06] VERIFIED ACTION #4;5