What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727A+6; BS 727A+10; BS 727A+14; BS 727B+5; BS 727B+10; BS 727B+11; BS 727B+14; BS 727C+6; BS 727C+10; BS 727C+12. / [01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE 53-00-53-1A-2<BR>AND IDENTIFICATION 53-60-53-01-2 <BR><BR>REMOVED CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727A+6 IAW IAW SRM 51-10-02 PARAGRAPH 15 ;EVALUATED REWORKED AREA AS FOLLOW: DIMENSIONS L=1.0' W= 0.900' DEPTH:0.014' <BR>ORIGINAL MATERIAL THICKNESS 0.040' PER BAC1496-377 REMAINING THICKNESS:0.026' AND FOUND TO BE OUT LIMITS; ALLOWABLE DAMAGE IAW SRM 53-00-53-1A-2<BR>TOOL USED DEPTH GAUGE <BR>ID= ATS 2472 S/N UNKWOWN DUE= 12/2022;[02] UPDATED MEASUREMENTS;[03] CORRECTION ACTION 1:<BR>VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE SRM 53-00-53-1A-2<BR>AND IDENTIFICATION SRM 53-60-53-01-2;[04] INSPECTED ACTION 1-3; PARTIAL STEPS 1-10. VERIFIED MEASUREMENT TABLE;[05] THIS FAULT WILL BE ACCOMPLISHED ON CARD TTG8Q00F4LAQ;[06] UPDATED INFORMATION REQUIRED MATERIAL<BR>CANTIDAD=1 N/P + 146A7502-51;[07] UPDATED MEASUREMENT TABLE ITEM 14;[08] ALL STEPS COMPLETED;[09] VERIFIED CORRECTIVE ACTION 8