What was found
PANEL #241ADF; HAS CORRODED INSERTS; AND EDGE DAMAGE / REMOVED DELAMINATED SKIN PLIESAPPLIED BMS 5-28; TY 19 POTTING COMPOUND (LOT# AK2DP3091K) TO AREAS OF EXPOSED CORE ACCORDING TO SRM 53-00-50-2R-1; PARA. 3.G. <BR><BR>AREAS REQUIRE ELEVATED TEMPERATURE CURE.<BR><BR>POTTING COMPOUND MIX TIME: 14:00; 10/7/2022;[05] VERIFIED CORRECTIVE ACTION ITEM 4. CURED POTTING COMPOUND; SANDED SMOOTH TO INITIAL SURFACE; CLEANED REPAIR AREAS AND FABRICATED REPAIR PLIES USING BMS 9-3ST1581 LOT#1502472-1 IAW SRM 53-00-50-2R-1 PARA 3.H-K. INSTALLED PLIES WITH BMS8-201 LOT NUMBER AK2EP8210K; VACUUM BAGGED AND VERIFIED SATISFACTORY 5X5 USING VACUUM GAUGE ID: ATS2797 DUE: 10/2023; WORK PERFORMED IAW SRM 53-00-50-2R-1 PARAGRAPH 3.K.(1).(B-C) AND L.(1CURED PLIES WITH A HEAT LAMP USING THERMOMETER ID: ATS1776 DUE: 08/2023 IAW SRM 53-00-50-2R-1 PARAGRAPH 3.M.(1)CURED BLIND INSERTS POTTING COMPOUND ACCORDING TO SRM 53-00-50-2R-1; PARA. 3.N; AND SRM 53-00-50-2R-0; PARA'S 5.S.(2).(G) AND (H).<BR><BR>HOT BOND CONSOLE ID: ATS2802; DUE: 10/2023;[14] INSTALLED AND CURED 20EA. THRU INSERTS USING BMS 5-107; CL 1 ADHESIVE (LOT# AK1KP9159K) ACCORDING TO SRM 53-00-50-2R-1; PARA. 3.N; SRM 53-00-50-2R-0; PARA'S 5.S.(1).; AND DWG# 147A5810; SHEET#14<BR><BR>REPLACED MISSING/REMOVED SKYFLEX NON-STICK TAPE WITH NEW TAPE (LOT# 1459689-1) ACCORDING TO DWG# 147A5810; SHEET#14; E-CODE E6634.<BR><BR>THERMOMETER ID: ATS2208; DUE: 10/2022<BR><BR>REPAIRS COMPLETED ACCORDING SRM 53-00-50-2R-1.