What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500B+2; BS 500B+6; BS 500B+10; BS 500B+14; BS 500C+6; BS 500C+10; BS 500C+14. / [01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT AT LBL24;BS500B+6;MEASURES:L=.9;W=.65;D=.009';ORIGINAL MATERIAL TICKNESS IS 0.040';REMAINING TICKNESS:0.031';FOUND TO BE OUT LIMITS;IAW SRM 53-00-53-1A-2;PARAG.4A(2) DETAIL D FIG.103 AND SRM 53-30-53-0I-2 IDENTIFICATION 2 TABE 2.TOOL USED:ATS2677;S/N UNKNOWN;DUE:11/2022.;[03] COMPLETED STEPS#1-2-3-4-5-6-7.;[04] VERIFIED CORRECTIVE ACTION STEPS 1;2 AND 3.;[05] THIS FAULT WILL BE ACCOMPLISHED ON CARD # TTG8Q00FFLT4;[06] VERIFIED CORRECTIVE ACTIONS STEP 5 AND MEASUREMENTS TABLE.