What was found
CRACK LEADING EDGE RIB ON THE L/E HSS 105.26, RT HORIZONTAL STAB. REJECTED RIB INSTALLATION ON RT HORIZONTAL STAB, DUE TO FOUND TOOL MARK LEADING EDGE SKIN. REPLACED THE RIB ON THE RT HORIZONTAL STAB IAW SRM 51-10-02, ITEM 9, AND DWG 186A1001, REV A, SHEET 10.