What was found
MID CABIN FLOORBOARD 242AF HAD COMPOSITE PULLED FIBERS ON UPPER SIDE. EVALUATED DAMAGE, REPAIRABLE IAW SRM 53-00-50-2R-1, REPAIR 1, TAP TESTED GOOD NO DELAMINATION NOTED. CLEANED, AND PREPPED IAW SRM 53-00-50-2R-1, PAR 3, STEPS A, C, E, AND J. BONDED REPAIR PLIES IAW SRM 53-00-50-2R-1, PAR 3, STEPS K, L, AND M. TAP TESTED GOOD. REPAIRED THE FLOOR BOARD IAW SRM 53-00-50-2R-1.