What was found
FWD CABIN FLIGHT DECK ENTRY DOOR RT POST UPPER AREA INTERCOSTAL HOLES ENLONGATED. TRIMMED EDGE DAMAGE HOLES IAW SRM 53-00-04-1A-1, FIGURE 102, DETAIL G. PERFORMED HFEC AROUND PERIMETER OF TRIMMED OUT AREAS IAW NDTM PART 6, 51-00-00, PROCEDURE 23. NO CRACKS. FOUND OUT OF LIMITS IAW SRM 53-00-04-1A-1, FIG 102, DETAIL G. REMOVED THE INTERCOSTAL IAW SRM 51-40-02-0G-0. LOCATED & DRILLED A NEW INTERCOSTAL IAW SRM 51-40-05-0G-0. TREATED AND PRIME IAW SRM 51-20-0-0G-0. INSTALLED THE NEW INTERCOSTAL IAW SRM 51-40-02-0G-0.