FWD CABIN, BS 312, LBL 55, WL 208.1 FLOOR FITTING WAS CORRODED. REMOVED AND REPLACED THE FLOOR TIEDOWN FITTING IAW 51-10-15-1A-1 AND 51-40-02-0G-0.