What was found
EXT GROUND POWER SERVICE DOOR CUTOUT IS CRACKED AT LOWER EDGE. CUT AND REMOVED DAMAGED SECTION IAW SRM 53-10-15-2R-4 SECTION 4.B-C. ACCOMPLISHED 10X VISUAL INSPECTION OF TRIM OUT AREA IAW SRM 53-10-15-2R-4 SECTION C, (6). NO DEFECTS NOTED. ACCOMPLISHED HFEC IAW NDT PART 6 51-00-00, PROCEDURE 23, AT TRIMOUT AND INTERIOR STRUCTURE. NO DEFECTS NOTED. ACCOMPLISHED INSURANCE CUT AFTER HFEC INSPECTION IAW SRM 53-10-15-2R-4 SECTION 4. C (7). LOCATED; DRILLED AND FABRICATED DOUBLER AND FILLER IAW SRM 53-10-15-2R-4 SECTION 2. E-J. APPLIED CHEMICAL CONVERSION AND PRIMER IAW SRM 53-10-15-2R-4 SECTION 4.K-L. INSTALLED REPAIR IAW SRM 53-10-15-2R-4, SECTION 4.M.