What was found
CORROSION ON AFT CARGO, CARGO TRACK, RBL 8, BS 767+6. REWORKED, ORIGINAL THICKNESS :0.063' REMAINING THICKNESS 0.040' OUT ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-53-1A-2, ALLOWABLE DAMAGE 2, FIGURE 103, DETAIL D. REMOVED UPPER FLANGE OF JOGGLE AREA ON THE CARGO TRACK IAW SRM 53-00-53-2R-2, STEPS 4,D. ACCOMPLISHED HFEC INSPECTION ALONG CUT EDGES IAW NDTM D6-37239, PART 6, 51-00-00, PROC 23. NO CRACKS FOUND. FABRICATED, LOCATED, AND DRILLED A REPAIR CHANNEL IAW SRM 51-40-05, AND SRM 53-00-53-2R-2, REPAIR 2, FIG 203. APPLIED CHEMICAL CONVERSION COATING ON REPAIR IAW SOPM 20-41-02. APPLIED PRIMER ON REPAIR IAW SRM 51-20-01-0G-0. INSTALLED THE REPAIR ON THE CARGO TRACK IAW SRM 53-00-53-2R-2, AND SRM 51-40-02-0G-0.