What was found
CRACKED BREAK PANEL STA 540; RBL 1; WL 207.<[01] REMOVED CRACKED BREAK PANEL AT STA 540 RBL1 WL 207 PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILL NEW BREAK PANEL AT STA540 BLO-RBL25 PER SRM 51-40-05. OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION #2;[04] ADDED THICKNESS F MATERIAL;[05] VERIFIED THICKNESS OF MATERIAL;[06] INSTALLED NEW BREAK PANEL AT STA540; BL-RB25 WL 207 PER SRM 51-40-02-0G-0;[07] ADDING DWG 143A5240;[08] VERIFIED DWG 143A5240;[09] VERIFIED MEASUREMENTS<BR>VERIFIED CORRECTIVE ACTION #6