What was found
LAV SERVICE DOOR HAS CORROSION ON INNER SURFACE AT BONDING JUMPER ATTACH POINT<[01] EVALUATED CORROSION ON LAV SERVICE DOOR AT BONDING JUMPER ATTACH POINT; FOUND 0.030 REMOVED FROM ORIG 0.100 IN 1'X1' FOUND TO BE OUT OF LIMITS PER SRM 52-40-01-1A-4 USING DIAL DEPTH GAUGE ATS 2473 DUE 08/2023;[02] VERIFIED CORRECTIVE ACTION #1 AND MEASUREMENT FIELD.;[03] RECEIVED NEW LAV DOOR ON PO #904689 REMOVED LAV DOOR INSTALLED NEW LAV DOOR USING BONDING METER ID # ATS1571 DUE 08/2023 BOND CHECK GOOD IAW MM 52-49-07;[04] VERIFIED CORRECTIVE ACTION 1